TLS Online TPP Program

#Question id: 14116


Which of the following statements are CORRECT when a protein sequence database is searched using the BLAST algorithm? 
P. A larger E-value indicates higher sequence similarity 
Q. E-value < 10^-10 indicates sequence homology 
R. A higher BLAST score indicates higher sequence similarity 
S. E-value > 10^10 indicates sequence homology 

#Section 7: Recombinant DNA technology and Other Tools in Biotechnology
  1. P, Q and R only
  2. Q and R only 
  3. P, R and S only
  4. P and S only
More Questions
TLS Online TPP Program

#Question id: 14261

#Section 5: Bioprocess Engineering and Process Biotechnology

C. roseus cells immobilized in Ca-alginate beads of diameter 0.5 mm are used for production of indole alkaloids (IA) in a fluidized-bed bioreactor. The rate limiting nutrient is glucose and no intraparticle diffusion limitations exist. Use the following data: Flow rate of the feed: Q = 1 l/h, Glucose in the feed: So = 30 g/l, Plant Cell Concentration: X = 6 g/l reac. The rate constant for IA formation: k = 5 d-1 (g/l)^-1 Ks = 0.4 g/l, Column diameter: Do = 0.15 m. Growth is negligible and Monod kinetics is valid. If Yp/s is 0.02 g IA/g glu, determine IA concentration in the effluent.
_______________

TLS Online TPP Program

#Question id: 14262

#Section 5: Bioprocess Engineering and Process Biotechnology

The BOD5 value of a waste-water feed stream to an activated-sludge unit is S0 = 300 mg/l, and the effluent is desired to be S = 30 mg/l. The feed flow rate is F = 2× 10^7 l/day. For the recycle ratio of α = 0.5 and a steady-state biomass concentration of X = 5 g/l, Use the following kinetic parameters:

 
calculate Required reactor volume (V). 
_______________10^6

TLS Online TPP Program

#Question id: 14263

#Section 5: Bioprocess Engineering and Process Biotechnology

The BOD5 value of a waste-water feed stream to an activated-sludge unit is S0 = 300 mg/l, and the effluent is desired to be S = 30 mg/l. The feed flow rate is F = 2× 10^7 l/day. For the recycle ratio of α = 0.5 and a steady-state biomass concentration of X = 5 g/l, Use the following kinetic parameters:

 
calculate Biomass concentration in recycle (Xr).

TLS Online TPP Program

#Question id: 14264

#Section 5: Bioprocess Engineering and Process Biotechnology

The BOD5 value of a waste-water feed stream to an activated-sludge unit is S0 = 300 mg/l, and the effluent is desired to be S = 30 mg/l. The feed flow rate is F = 2× 10^7 l/day. For the recycle ratio of α = 0.5 and a steady-state biomass concentration of X = 5 g/l, Use the following kinetic parameters:

 
calculate Hydraulic residence time
______________

TLS Online TPP Program

#Question id: 14265

#Section 5: Bioprocess Engineering and Process Biotechnology

For the activated-sludge, the specific growth rate of cells is given by 


 

The following parameter values are known: F = 500 l/h, α = 0.4, ɣ = 0.1, Xe = 0, V = 1500 l, Ks = 10 mg/l, µm = 1 h-1 , kd = 0.05 h-1 , S0 = 1000 mg/l, Y M X/S = 0.5 g dw/g substrate. Calculate the substrate concentration (S) in the reactor at steady state. -------------------------

TLS Online TPP Program

#Question id: 14266

#Section 5: Bioprocess Engineering and Process Biotechnology

For the activated-sludge, the specific growth rate of cells is given by 


 

The following parameter values are known: F = 500 l/h, α = 0.4, ɣ = 0.1, Xe = 0, V = 1500 l, Ks = 10 mg/l, µm = 1 h-1 , kd = 0.05 h^-1 , S0 = 1000 mg/l, Y M X/S = 0.5 g dw/g substrate.. Calculate the cell concentration in the reactor.