TLS Online TPP Program

#Question id: 1119


Phosphorylation cascades involving a series of protein kinases are useful for cellular signal transduction because they:

#Section 3: Genetics, Cellular and Molecular Biology
  1. are species specific

  2. always lead to the same cellular response

  3. amplify the original signal many times

  4. counter the harmful effects of phosphatases

More Questions
TLS Online TPP Program

#Question id: 14430

#Section 5: Bioprocess Engineering and Process Biotechnology

Which is not correctly match, effect of process variables on mass transfer characteristics?

Process variablemass transfer characteristics
P. P/V oxygen transfer rate
q. Impeller tip speedmixing time
r. Reynoldsnumber shear rate

TLS Online TPP Program

#Question id: 14431

#Section 5: Bioprocess Engineering and Process Biotechnology

the centrifugal separation of biomass of 80um sized cells of density 1.04kgm^-3 was carried out in a tubular centrifuge having a diameter of 15cm and rotating at 1200 rev/min. calculate the residence time if distance between the liquid surface and the axis of rotation was 0.8cm, the liquid viscosity were 1.0kgm^-3 and 0.013 gcm^-ls-1respectively. 

TLS Online TPP Program

#Question id: 14432

#Section 5: Bioprocess Engineering and Process Biotechnology

the centrifugal separation of biomass of 80um sized cells of density 1.04kgm^-3 was carried out in a tubular centrifuge having a diameter of 15cm and rotating at 1200 rev/min. the axis of rotation was 0.8cm, the liquid viscosity were 1.0kgm^-3 and 0.013 gcm-ls^-1 respectively. Calculate the volumetric capacity of the centrifuge if its length was 40cm? 

TLS Online TPP Program

#Question id: 14433

#Section 5: Bioprocess Engineering and Process Biotechnology

the centrifugal separation of biomass of 80um sized cells of density 1.04kgm^-3 was carried out in a tubular centrifuge having a diameter of 15cm and rotating at 1200 rev/min. the axis of rotation was 0.8cm, the liquid viscosity were 1.0kgm-3 and 0.013 gcm-^ls^-1 respectively. centrifuge length is 40cm, calculate the  factor? 

TLS Online TPP Program

#Question id: 14434

#Section 5: Bioprocess Engineering and Process Biotechnology

the centrifugal separation of biomass of 80um sized cells of density 1.04kgm-3 was carried out in a tubular centrifuge having a diameter of 15cm and rotating at 1200 rev/min. the axis of rotation was 0.8cm, the liquid viscosity was 1.0kgm-3 and 0.013 gcm-ls-1 respectively. centrifuge length is 40cm, what will be the time required for centrifuging 1000 litres of broth? 

TLS Online TPP Program

#Question id: 14435

#Section 5: Bioprocess Engineering and Process Biotechnology

Differential centrifugation separates the particle which is different in