TLS Online TPP Program

#Question id: 4144


The Wobble Hypothesis suggests that:

#Section 3: Genetics, Cellular and Molecular Biology
  1. flexibility in base pairing occurs between the third base of a codon and the corresponding base in its anticodon 

  2. flexibility in base pairing only occurs for inosine as it can pair with U, C or A at its second position 

  3. flexibility in base pairing occurs between the second first base of a codon and the corresponding base in its anticodon 

  4. flexibility in base pairing only occurs for inosine as it can pair with U, G or A as its third position 

More Questions
TLS Online TPP Program

#Question id: 14431

#Section 5: Bioprocess Engineering and Process Biotechnology

the centrifugal separation of biomass of 80um sized cells of density 1.04kgm^-3 was carried out in a tubular centrifuge having a diameter of 15cm and rotating at 1200 rev/min. calculate the residence time if distance between the liquid surface and the axis of rotation was 0.8cm, the liquid viscosity were 1.0kgm^-3 and 0.013 gcm^-ls-1respectively. 

TLS Online TPP Program

#Question id: 14432

#Section 5: Bioprocess Engineering and Process Biotechnology

the centrifugal separation of biomass of 80um sized cells of density 1.04kgm^-3 was carried out in a tubular centrifuge having a diameter of 15cm and rotating at 1200 rev/min. the axis of rotation was 0.8cm, the liquid viscosity were 1.0kgm^-3 and 0.013 gcm-ls^-1 respectively. Calculate the volumetric capacity of the centrifuge if its length was 40cm? 

TLS Online TPP Program

#Question id: 14433

#Section 5: Bioprocess Engineering and Process Biotechnology

the centrifugal separation of biomass of 80um sized cells of density 1.04kgm^-3 was carried out in a tubular centrifuge having a diameter of 15cm and rotating at 1200 rev/min. the axis of rotation was 0.8cm, the liquid viscosity were 1.0kgm-3 and 0.013 gcm-^ls^-1 respectively. centrifuge length is 40cm, calculate the  factor? 

TLS Online TPP Program

#Question id: 14434

#Section 5: Bioprocess Engineering and Process Biotechnology

the centrifugal separation of biomass of 80um sized cells of density 1.04kgm-3 was carried out in a tubular centrifuge having a diameter of 15cm and rotating at 1200 rev/min. the axis of rotation was 0.8cm, the liquid viscosity was 1.0kgm-3 and 0.013 gcm-ls-1 respectively. centrifuge length is 40cm, what will be the time required for centrifuging 1000 litres of broth? 

TLS Online TPP Program

#Question id: 14435

#Section 5: Bioprocess Engineering and Process Biotechnology

Differential centrifugation separates the particle which is different in 

TLS Online TPP Program

#Question id: 14436

#Section 5: Bioprocess Engineering and Process Biotechnology

Equation for Langmuir adsorption?