TLS Online TPP Program

#Question id: 19694


How to calculate heart rate from ECG?
a. by counting the number of QRS complexes
b. by counting the number of R Waves
c. by counting the number of P Waves
d. by counting the number of T Waves

#SCPH06 I Botany
  1. a & b
  2. b & c
  3. c & d
  4. a & c
More Questions
TLS Online TPP Program

#Question id: 14296

#SCPH05 I Biotechnology

A two-stage chemostat system is used for production of secondary metabolite. The volume of each reactor is 0.5 m3; the flow rate of feed is 50 l h- 1. Mycelial growth occurs in the first reactor; the second reactor is used for product synthesis. The concentration of substrate in the feed is 10 gl-1. Kinetic and yield parameters for the organism are:

                                                            

Assume that product synthesis is negligible in the first reactor and growth is negligible in the second reactor. Determine cell concentrations entering the second reactor.

______________________

TLS Online TPP Program

#Question id: 14297

#SCPH05 I Biotechnology

A two-stage chemostat system is used for production of secondary metabolite. The volume of each reactor is 0.5 m3; the flow rate of feed is 50 l h- 1. Mycelial growth occurs in the first reactor; the second reactor is used for product synthesis. The concentration of substrate in the feed is 10 gl-1. Kinetic and yield parameters for the organism are:

                                                            

Assume that product synthesis is negligible in the first reactor and growth is negligible in the second reactor. Determine substrate concentrations entering the second reactor.

________________

TLS Online TPP Program

#Question id: 14300

#SCPH05 I Biotechnology

A 15-m 3 chemostat is operated with dilution rate 0.1 h-1. A continuous steriliser with steam injection and flash cooling delivers sterilized medium to the fermenter. Medium in the holding section of the steriliser is maintained at 130⁰C The concentration of contaminants in the raw medium is 105 ml-l; an acceptable contamination risk is one organism every 3 months. The Arrhenius constant and activation energy for thermal death are estimated to be 7.5 × 1039 h-1 and 288.5 kJ gmol- 1, respectively. The steriliser pipe inner diameter is 12 cm. At 130⁰C the liquid density is 1000 kg m- 3 and the viscosity is 4 kg m- 1 h- 1. Assuming perfect plug flow, determine the length of the holding section.   __________________

TLS Online TPP Program

#Question id: 14301

#SCPH05 I Biotechnology

Pseudomonas sp. has a mass doubling time of 2.4 h when grown on acetate. The saturation constant using this substrate is 1.3 g/l (which is unusually high), and cell yield on acetate is 0.46 g cell/g acetate. If we operate a chemostat on a feed stream containing 38 g/l acetate, find the Cell concentration when the dilution rate is one-half of the maximum?

                ___________________