GenBank, the nucleic acid sequence database is maintained by

#Section 7: Recombinant DNA technology and Other Tools in Biotechnology
  1. Brookhaven laboratory
  2. DNA database of Japan (DDBJ)
  3. European molecular biology laboratory
  4. National centre for biotechnology information
More Questions
TLS Online TPP Program

#Question id: 14226

#Section 5: Bioprocess Engineering and Process Biotechnology

A fermenter is maintained at 35⁰C by water circulating at a rate of 0.5 kg s^-1 in a cooling coil inside the vessel. The inlet and outlet temperatures of the water are 8⁰C and 15⁰C respectively. The length of the cooling coil is increased by 50%. In order to maintain the same fermentation temperature, the rate of heat removal must be kept the same. Determine the new cooling-water flow rate and outlet temperature by carrying out the following calculations. The heat capacity of the cooling water can be taken as 4.18 kJ kg^- 1 o C^- 1. Determine the mean temperature difference with the original coil.

TLS Online TPP Program

#Question id: 14227

#Section 5: Bioprocess Engineering and Process Biotechnology

A fermenter is maintained at 35⁰C by water circulating at a rate of 0.5 kg s^-1 in a cooling coil inside the vessel. The inlet and outlet temperatures of the water are 8⁰C and 15⁰C respectively. The length of the cooling coil is increased by 50%. In order to maintain the same fermentation temperature, the rate of heat removal must be kept the same. Determine the new cooling-water flow rate and outlet temperature by carrying out the following calculations. The heat capacity of the cooling water can be taken as 4.18 kJ kg^- 1 o C^- 1. Evaluate UA for the original coil. ________________

TLS Online TPP Program

#Question id: 14228

#Section 5: Bioprocess Engineering and Process Biotechnology

A fermenter is maintained at 35⁰C by water circulating at a rate of 0.5 kg s^-1 in a cooling coil inside the vessel. The inlet and outlet temperatures of the water are 8⁰C and 15⁰C respectively. The length of the cooling coil is increased by 50%. In order to maintain the same fermentation temperature, the rate of heat removal must be kept the same. Determine the new cooling-water flow rate and outlet temperature by carrying out the following calculations. The heat capacity of the cooling water can be taken as 4.18 kJ kg^- 1 o C^- 1. If the length of the coil is increased by 50⁰C the area available for heat transfer, A ', also increases by 50% so that A' = 1.5 A. The value of the overall heat-transfer coefficient is not expected to change very much. For the new coil, what is the value of UA’  ______________

TLS Online TPP Program

#Question id: 14229

#Section 5: Bioprocess Engineering and Process Biotechnology

A fermenter is maintained at 35⁰C by water circulating at a rate of 0.5 kg s^-1 in a cooling coil inside the vessel. The inlet and outlet temperatures of the water are 8⁰C and 15⁰C respectively. The length of the cooling coil is increased by 50%. In order to maintain the same fermentation temperature, the rate of heat removal must be kept the same. Determine the new cooling-water flow rate and outlet temperature by carrying out the following calculations. The heat capacity of the cooling water can be taken as 4.18 kJ kg^- 1 o C^- 1. By how much are the cooling-water requirements reduced after the new coil is installed?_____________

TLS Online TPP Program

#Question id: 14230

#Section 5: Bioprocess Engineering and Process Biotechnology

In current service, 20 kg s^-1 cooling water at 12⁰C must be circulated through a coil inside a fermenter to maintain the temperature at 37⁰C The coil is 150 m long with pipe diameter 12 cm; the exit water temperature is 28⁰C After the inner and outer surfaces of the coil are cleaned it is found that only 13 kg s^-1 cooling water is required to control the fermentation temperature. Calculate the overall heat-transfer coefficient before cleaning. _____________

TLS Online TPP Program

#Question id: 14231

#Section 5: Bioprocess Engineering and Process Biotechnology

In current service, 20 kg s^-1 cooling water at 12⁰C must be circulated through a coil inside a fermenter to maintain the temperature at 37⁰C The coil is 150 m long with pipe diameter 12 cm; the exit water temperature is 28⁰C After the inner and outer surfaces of the coil are cleaned it is found that only 13 kg s^-1 cooling water is required to control the fermentation temperature. Calculate the overall heat-transfer coefficient before cleaning. What fraction of the total resistance to heat transfer before cleaning was due to fouling deposits?____________