A steam steriliser is used to sterilise liquid medium for fermentation.
The initial concentration of contaminating organisms is 108 per
litre. For design purposes, the final acceptable level of contamination is
usually taken to be 10-3cells; this corresponds to a risk that one
batch in a thousand will remain contaminated even after the sterilisation
process is complete. For how long should 1 m3 medium be treated if
the temperature is 121⁰C ________________.