TLS Online TPP Program

#Question id: 631


Two curves showing the rate versus substrate concentration are shown below for an enzyme-catalyzed reaction. One curve is for the reaction in the presence of substance X. The other curve is for data in the absence of substance X. Examine the curves and tell which statement below is false.

#Section 2: General Biology
  1. X is an activator of the enzyme.

  2. The enzyme exhibits non-Michaelis-Menten kinetics.

  3. X is likely an allosteric modulator.

  4. X is a competitive inhibitor.

More Questions
TLS Online TPP Program

#Question id: 14224

#Section 5: Bioprocess Engineering and Process Biotechnology

Heat is transferred from one fluid to a second fluid across a metal wall. The film coefficients are 1.2 and 1.7kW m^-2 K^- 1. The metal is 6-mm thick and has a thermal conductivity of 19 W m^-1 K^-1. On one side of the wall there is a scale deposit with a fouling factor estimated at 19 W m^-1 K^-1. What is the overall heat-transfer coefficient?

TLS Online TPP Program

#Question id: 14225

#Section 5: Bioprocess Engineering and Process Biotechnology

A fermenter is maintained at 35⁰C by water circulating at a rate of 0.5 kg s^-1 in a cooling coil inside the vessel. The inlet and outlet temperatures of the water are 8⁰C and 15⁰C respectively. The length of the cooling coil is increased by 50%. In order to maintain the same fermentation temperature, the rate of heat removal must be kept the same. Determine the new cooling-water flow rate and outlet temperature by carrying out the following calculations. The heat capacity of the cooling water can be taken as 4.18 kJ kg^- 1 o C^- 1. From a steady-state energy balance on the cooling water, calculate the rate of cooling with the original coil ___________________.

TLS Online TPP Program

#Question id: 14226

#Section 5: Bioprocess Engineering and Process Biotechnology

A fermenter is maintained at 35⁰C by water circulating at a rate of 0.5 kg s^-1 in a cooling coil inside the vessel. The inlet and outlet temperatures of the water are 8⁰C and 15⁰C respectively. The length of the cooling coil is increased by 50%. In order to maintain the same fermentation temperature, the rate of heat removal must be kept the same. Determine the new cooling-water flow rate and outlet temperature by carrying out the following calculations. The heat capacity of the cooling water can be taken as 4.18 kJ kg^- 1 o C^- 1. Determine the mean temperature difference with the original coil.

TLS Online TPP Program

#Question id: 14227

#Section 5: Bioprocess Engineering and Process Biotechnology

A fermenter is maintained at 35⁰C by water circulating at a rate of 0.5 kg s^-1 in a cooling coil inside the vessel. The inlet and outlet temperatures of the water are 8⁰C and 15⁰C respectively. The length of the cooling coil is increased by 50%. In order to maintain the same fermentation temperature, the rate of heat removal must be kept the same. Determine the new cooling-water flow rate and outlet temperature by carrying out the following calculations. The heat capacity of the cooling water can be taken as 4.18 kJ kg^- 1 o C^- 1. Evaluate UA for the original coil. ________________

TLS Online TPP Program

#Question id: 14228

#Section 5: Bioprocess Engineering and Process Biotechnology

A fermenter is maintained at 35⁰C by water circulating at a rate of 0.5 kg s^-1 in a cooling coil inside the vessel. The inlet and outlet temperatures of the water are 8⁰C and 15⁰C respectively. The length of the cooling coil is increased by 50%. In order to maintain the same fermentation temperature, the rate of heat removal must be kept the same. Determine the new cooling-water flow rate and outlet temperature by carrying out the following calculations. The heat capacity of the cooling water can be taken as 4.18 kJ kg^- 1 o C^- 1. If the length of the coil is increased by 50⁰C the area available for heat transfer, A ', also increases by 50% so that A' = 1.5 A. The value of the overall heat-transfer coefficient is not expected to change very much. For the new coil, what is the value of UA’  ______________

TLS Online TPP Program

#Question id: 14229

#Section 5: Bioprocess Engineering and Process Biotechnology

A fermenter is maintained at 35⁰C by water circulating at a rate of 0.5 kg s^-1 in a cooling coil inside the vessel. The inlet and outlet temperatures of the water are 8⁰C and 15⁰C respectively. The length of the cooling coil is increased by 50%. In order to maintain the same fermentation temperature, the rate of heat removal must be kept the same. Determine the new cooling-water flow rate and outlet temperature by carrying out the following calculations. The heat capacity of the cooling water can be taken as 4.18 kJ kg^- 1 o C^- 1. By how much are the cooling-water requirements reduced after the new coil is installed?_____________