TLS Online TPP Program

#Question id: 15896


Somatic embryos are bipolar structures in that they have a radicle and a plumule,
a) Plumular end sometimes oriented toward the centre of callus or cell mass 
b) Plumular end always sticks out from the cell mass 
c) The radicular end is always oriented toward the centre of callus or cell mass
d) Radicular end is sometimes sticks out from the cell mass 
Which of the following is the well defined bipolar structure of somatic embryos

#Section 6: Plant, Animal and Microbial Biotechnology
  1. a and d
  2. b and c
  3. Only b
  4. Only d
More Questions
TLS Online TPP Program

#Question id: 14428

#Section 5: Bioprocess Engineering and Process Biotechnology

The sensor, which is an integral part of fermentation equipment, the measured value cannot used directly for control. this type of controlling system is called  

TLS Online TPP Program

#Question id: 14429

#Section 5: Bioprocess Engineering and Process Biotechnology

Which one of the following constants is represented by Kp?

TLS Online TPP Program

#Question id: 14430

#Section 5: Bioprocess Engineering and Process Biotechnology

Which is not correctly match, effect of process variables on mass transfer characteristics?
Process variable                     mass transfer characteristics
P. P/V                              -          oxygen transfer rate
q. Impeller tip speed     -          mixing time
r. Reynolds                     -          number shear rate 

TLS Online TPP Program

#Question id: 14431

#Section 5: Bioprocess Engineering and Process Biotechnology

the centrifugal separation of biomass of 80um sized cells of density 1.04kgm^-3 was carried out in a tubular centrifuge having a diameter of 15cm and rotating at 1200 rev/min. calculate the residence time if distance between the liquid surface and the axis of rotation was 0.8cm, the liquid viscosity were 1.0kgm^-3 and 0.013 gcm^-ls-1respectively. 

TLS Online TPP Program

#Question id: 14432

#Section 5: Bioprocess Engineering and Process Biotechnology

the centrifugal separation of biomass of 80um sized cells of density 1.04kgm^-3 was carried out in a tubular centrifuge having a diameter of 15cm and rotating at 1200 rev/min. the axis of rotation was 0.8cm, the liquid viscosity were 1.0kgm^-3 and 0.013 gcm-ls^-1 respectively. Calculate the volumetric capacity of the centrifuge if its length was 40cm? 

TLS Online TPP Program

#Question id: 14433

#Section 5: Bioprocess Engineering and Process Biotechnology

the centrifugal separation of biomass of 80um sized cells of density 1.04kgm^-3 was carried out in a tubular centrifuge having a diameter of 15cm and rotating at 1200 rev/min. the axis of rotation was 0.8cm, the liquid viscosity were 1.0kgm-3 and 0.013 gcm-^ls^-1 respectively. centrifuge length is 40cm, calculate the  factor?